Pentair intelliflo display not working

A Pump That Knows A Pool's Flow A pool that is crystal clear and inviting is key to the perfect backyard oasis. The IntelliFlo3® VSF Pool Pump leverages built-in sensorless flow control for optimum water flow and adjusts to pool conditions, keeping pools performing at their best.

Dec 15, 2019 · Dec 15, 2019. #1. I just installed an Intelliflo VF and it operates in standalone mode. When I connect it to the Aqualink (ver T.2) with iAqualink 2.0, the pump will not run. The "status" screen shows the Intelliflo VF at 0 rpm and 0 flow, so the communication seems fine. I also disconnected my RS4 All button keypad. Sounds like something simple. 2.0 or higher. • Instructions on how to factory reset a Pentair IntelliFlo pump. ... If these instructions do not work, refer to the Pentair pump's manual for ...Jan 21, 2014 · Plano, TX. May 4, 2017. #37. Have to say I was fairly skeptical on this fix (my LCD screen on Pentair has been blank for a couple of years) but opted to try it as described in this thread. Pics and details from Rwhite692 were very helpful. Spent $4 for foam weatherstrips at HD and that was pretty much it.

Did you know?

Oceanside, CA. Jan 13, 2019. #3. Jimrahbe said: Fred, ScreenLogic remembers the last setting so it is often hard to tell if it just presenting old info.. I suspect you have lost the wireless link between the ET and the Protocol adapter.. On the outside antenna, raise the hood and see if the green power light is on and that the RX and TX …May 18, 2023 · Yes the RS-485 cable.. A single speed pump is controlled by an Aux relay and does not use the RS-485 com port. A VS pump is controlled by the RS-485 cable and is not wired to any Aux relay. It sometimes takes a minute or two for the "Display not Active" screen to go away when you first go into the Service mode. Mar 1, 2020 · The computer drive for this Pentair Intelliflo VS pump Failed. The display shorted out, and no longer controllable. The how to steps for replacing the drive. Jun 30, 2019 · I have the ScreenLogic Config app on my iPhone. I went to the IntelliFlo Setup section and see Pump 1 and Pump 2 listed. Pump 1 is my main pump and Pump 2 is my cleaner pump. Both pumps are set to "none," which makes sense since neither was a IntelliFlo. Now that Pump 1 is an IntelliFlo, I know it's obvious that I should set it to VSF.

Things to make sure of... 1. When the EasyTouch is controlling your IntelliFlo, the pump's display should say "Display not active". 2. For the pump to run there has to be at least one Active Circuit scheduled in the EasyTouch and it needs to be on. Like the Pool Circuit as an example. 3.Started pool yesterday and pump was running great and it had run almost 24 hours when I noticed it had stopped working. No lights on the display. Intelichlor generator still has power. Checked power to the drive and have 250v. Not sure what to look for as far as voltage to the keypad. Turned the impeller through the skimmer and it spins freely.• Instructions on how to factory reset a Pentair IntelliFlo pump. These instruction may not work for all IntelliFlo Models. If these instructions do not work, refer to the Pentair pump’s manual for complete instructions on how to perform a factory reset. 1. If already connected to the Pump Converter Board, disconnect the black comm wire Offers 8 speed settings and on-board scheduling LCD screen with keypad for easy programming. ... This is my favorite pond pump, have two working all the time and ...

Pentair INTELLIFLO 2 VST Installation And User Manual (36 pages) VARIABLE SPEED PUMP. Brand: Pentair | Category: Water Pump | Size: 3.72 MB. Table of Contents. Table of Contents. 2. Important Pump Warning and Safety Instructions. 3. Pump Overview.1. Replace the keypad (Cheapest and simplest solution but there is conflicting info if this can be done) 2. Replace the complete drive assembly (Expensive but may be most reliable solution) 3. Bypass keypad with external/remote control system (Expense on order of replacing drive assembly)Jan 5, 2023. #1. Our Pentair superflo SF-N1-1A is broken - it makes a jamming sound when trying to turn on and then shuts down due to overheating. It was installed in 2017 so I’m guessing it’s at the end of its 5-7 year lifespan (per google). Local pool shop recommended replacing this 1HP unit with a Pentair IntelliFlo i2. ….

Reader Q&A - also see RECOMMENDED ARTICLES & FAQs. Pentair intelliflo display not working. Possible cause: Not clear pentair intelliflo display not working.

The pentair intelliflo display not working may be due to a malfunction or faulty connection. If you are experiencing this issue, ensure that the display is properly connected and check for any error codes or indicators on the display.Sep 22, 2016 · Push menu and scroll down to "Settings" and press "Select". Scroll down to "Intelliflo" and press "Select". Select "Pump 1". Pump Type should be "VS". Scroll down to "Speeds" and press "Select". You should see something like the following, your numbers may be different: RPM 1200 1/8. Circuit. Contact Us Still have questions on your Pentair IntelliFlo? Our customer service team is here to help you.Call: 1.800.831.7133 Find the support you need to connect your water devices to the Pentair Home and Pentair Pro apps. Pentair has FAQs and documentation to get you started.

Contact Us Still have questions on your Pentair IntelliFlo? Our customer service team is here to help you.Call: 1.800.831.7133 Find the support you need to connect your water devices to the Pentair Home and Pentair Pro apps. Pentair has FAQs and documentation to get you started.Our client called us stating the variable speed pool pump was not turning on and they are having to turning it on manually. Their home experienced a power ou...

pers 41 Troubleshooting a Pool Pump Motor Pentair Intelliflo Variable Speed pumps are great pumps, but occasionally parts fail and they need to be fixed.I get service calls from customers complaining...The Pentair Home app accepts a wide range of Pentair Connected water devices that can be used throughout a home to help your customers move, improve and enjoy their water. However, at this time, Pentair Home and Pentair Pro are not integrated with other smart home devices, or connected via voice with at home assistants like Alexa or Google Home. r34 pokemon animatedsouth topsail beach tide chart Jan 1, 2021. #1. I just installed a pentair intelliflo vsf pump with my jandy aqualink rev QQ controller. Wired both poles thru the filter pump relay as the jandy manual instructs, connected the rs485 wires (pin 2 yellow, pin 3green) as the online refs instruct. Pump properly displays “display not active”, set the controller to vf pump and ...#1 Similar threads found, but want to make sure I didn't miss an easier fix. My pump display went dead and the breaker was tripped. Reset the breaker and it … enhancement shaman leveling dragonflight Aug 4, 2022 · Intelliflo VS pump is supposed to have constant power and not wired through the filter pump relay. The Intelliflo VS pump should be controlled by the RS-485 comm line. What does the Intelliflo display show? If the pump can be controlled by its control panel then the RS-485 comm control to the pump is not active. The pentair intelliflo display not working may be due to a malfunction or faulty connection. If you are experiencing this issue, ensure that the display is properly connected and check for any error codes or indicators on the display. sam's club toledo gas pricessynonym for this is whyreddit i deleted my husband's youtube channel 600k subscribers Intelliflo VS does not start turning but powers on via intellicenter easytouch2 4 firmware 2.140. I had an issue with my pump that had been working for years. It lost communications. I had a spare cable and changed it and reset the pump and get the display not active like i should but the... ncaa top 25 football results Oct 4, 2023 · To fix the Pentair Intelliflo Display Not Working issue and get your pool pump working optimally again, it’s crucial to understand the potential origins of the problem. Electrical problems, particularly those related to the power supply, can often throw a wrench into the works of the IntelliFlo Display. Over time, the wiring and connections ... breckinridge county busted newspaperryobi trimmer blade replacementmatthew 5 nkj Loose wires and a malfunctioning timer can prevent the pump from turning on and off. Tighten the wires with the previously mentioned process, then listen to the clock closely. There should be a clicking sound if the clock is working properly on an external timer. Replace the internal timer if it won’t turn off.